PV infrared thermography
Screen operating modules and associated equipment for abnormal heat patterns.
Apply the agreed IEC TS 62446-3-based method; unsuitable conditions may require rescheduling.
Inspection & Energy
Find thermal anomalies and use separate electrical tests where deeper diagnosis is needed.
Radiometric PV thermography maps temperature patterns while modules are operating under suitable irradiance and environmental conditions.
EL imaging and I–V tracing test different electrical/physical characteristics and are separate from infrared imaging.
Geolocated anomaly mapping supports diagnosis; root cause and energy impact may require electrical or physical follow-up.
Screen operating modules and associated equipment for abnormal heat patterns.
Apply the agreed IEC TS 62446-3-based method; unsuitable conditions may require rescheduling.
Use a dedicated electrical/optical test to examine module defects.
Requires specialist equipment, electrical procedures and a separately confirmed vendor.
Measure current–voltage performance of selected modules or strings.
Test conditions, configuration and calibration must be recorded.
Check previously reported anomalies after remedial work.
Comparable conditions are required; repairs themselves are not included.
A thermal hotspot is an observation, not a root-cause diagnosis. Shading, soiling, connections and operating conditions may require electrical or physical confirmation.
Operating PV thermography needs suitable irradiance and electrical conditions. Electroluminescence is a different test and can use low-light/night conditions depending on the test setup.
They have separate equipment, personnel, access and electrical-safety requirements and must be selected in the scope.
The report identifies observations and investigation priorities. Energy impact depends on confirmed faults, operating data and completed remedies.
IEC TS 62446-3-based practice requires suitable, stable operating conditions; industry guidance tied to that standard uses at least 600 W/m² irradiance in the plane of the module for infrared inspection. The actual inspection plan records the measured conditions.
Collect radiometric infrared evidence under suitable operating and environmental conditions.
Identify module/string locations and distinguish observation from confirmed fault diagnosis.
Electroluminescence and I–V curve tracing are separate tests, not ordinary thermal-camera outputs.
Apply the agreed IEC TS 62446-3-based method; unsuitable conditions may require rescheduling.
Requires specialist equipment, electrical procedures and a separately confirmed vendor.
Test conditions, configuration and calibration must be recorded.
Comparable conditions are required; repairs themselves are not included.
Outdoor PV infrared thermography is covered by IEC TS 62446-3; practice tied to that standard uses at least 600 W/m² irradiance in the plane of the module with suitable stable conditions. IEA PVPS Task 13