Inspection & Energy

Inspection & Energy

Solar thermography (+ EL / I–V testing)

Find thermal anomalies and use separate electrical tests where deeper diagnosis is needed.

What you receive

  • Geolocated radiometric and visible imagery
  • Module/string anomaly register
  • Severity and verification worklist
  • Optional EL images and I–V test records
How we deliver

Scope & options

Radiometric PV thermography maps temperature patterns while modules are operating under suitable irradiance and environmental conditions.

EL imaging and I–V tracing test different electrical/physical characteristics and are separate from infrared imaging.

Geolocated anomaly mapping supports diagnosis; root cause and energy impact may require electrical or physical follow-up.

Explore 4 service variants

PV infrared thermography

Screen operating modules and associated equipment for abnormal heat patterns.

Apply the agreed IEC TS 62446-3-based method; unsuitable conditions may require rescheduling.

Electroluminescence (EL) testing

Use a dedicated electrical/optical test to examine module defects.

Requires specialist equipment, electrical procedures and a separately confirmed vendor.

I–V curve tracing

Measure current–voltage performance of selected modules or strings.

Test conditions, configuration and calibration must be recorded.

Post-repair reinspection

Check previously reported anomalies after remedial work.

Comparable conditions are required; repairs themselves are not included.

Useful to know

Terms, explained
Infrared thermography
Radiometric thermal imaging used to locate temperature anomalies under suitable operating conditions.
Electroluminescence (EL)
Electrical test imaging that can reveal module-cell defects not visible in ordinary thermal images.
I–V curve
Measured current-voltage response used to assess electrical performance of a module or string.
Does a hotspot prove a failed module?

A thermal hotspot is an observation, not a root-cause diagnosis. Shading, soiling, connections and operating conditions may require electrical or physical confirmation.

Can you do the same PV thermal test at night?

Operating PV thermography needs suitable irradiance and electrical conditions. Electroluminescence is a different test and can use low-light/night conditions depending on the test setup.

Are EL and I–V testing included automatically?

They have separate equipment, personnel, access and electrical-safety requirements and must be selected in the scope.

Will the report guarantee an energy-yield improvement?

The report identifies observations and investigation priorities. Energy impact depends on confirmed faults, operating data and completed remedies.

What sunlight condition is used for outdoor PV thermography?

IEC TS 62446-3-based practice requires suitable, stable operating conditions; industry guidance tied to that standard uses at least 600 W/m² irradiance in the plane of the module for infrared inspection. The actual inspection plan records the measured conditions.

Method & limitations

Collect radiometric infrared evidence under suitable operating and environmental conditions.

Identify module/string locations and distinguish observation from confirmed fault diagnosis.

Electroluminescence and I–V curve tracing are separate tests, not ordinary thermal-camera outputs.

Apply the agreed IEC TS 62446-3-based method; unsuitable conditions may require rescheduling.

Requires specialist equipment, electrical procedures and a separately confirmed vendor.

Test conditions, configuration and calibration must be recorded.

Comparable conditions are required; repairs themselves are not included.

Outdoor PV infrared thermography is covered by IEC TS 62446-3; practice tied to that standard uses at least 600 W/m² irradiance in the plane of the module with suitable stable conditions. IEA PVPS Task 13

Sources & references

Your project

Enquire

Solar thermography (+ EL / I–V testing)

Share your project details with our team. The confirmation tells you whether email delivery was accepted.

Help me ask
  • Do I need thermal screening, EL, I–V testing or a combination?
  • What conditions and asset layout data are needed for a valid inspection?
  • How will findings be matched to specific modules or strings?
Use ordinary words. A short problem description is enough. Do not include confidential or security-sensitive information.
Start with state and district/city. Exact boundaries can be provided later through an agreed channel.Leave blank if unknown.
An estimate is acceptable. Leave unknown rather than inventing a measurement.Leave blank if unknown.
Personal addresses are accepted for civilian enquiries and individual training.
More project detail Optional
This is a preference, not a confirmed mobilisation or delivery date.Leave blank if unknown.
State only a non-sensitive reference. A submitted standard is a requirement to review, not a claim of accreditation.
Examples: ground-only work, no cloud hosting, limited access. Do not include personal IDs, confidential documents or sensitive locations.
Which outputs do you need?
Optional: choose outputs within the approved scope, or leave undecided. This is a request, not automatic inclusion.
Optional specialist variants
Only independently verified variants may be selected for a commercial enquiry.
This authorises handling of this enquiry, not marketing, automatic vendor forwarding or public publication.

By submitting, you authorise Lotusmirk to use these details to respond to this enquiry. This does not opt you into marketing or automatic vendor sharing.